Energy Infrastructure & Services

Open Diesel Generator Set with Standby Power of 1100kVA/880kw

Starting from

SAR 532,931.25

About this product

Company Profile Beijing Xinda Gongchuang Machinery Equipment Co., Ltd. mainly supplies diesel generator sets and gas generator sets and spare parts for the units, including well-known international and domestic brands, including British Wilson, American Carter, Weichai, Yuchai, etc., with output power ranging from 7KW -2500KW.Choose from open, silent, containerized and trailer-mounted generator sets. Wilson product introduction FG Wilson is one of the world's largest suppliers of diesel and natural gas generator sets and is well-known in the industry. Wilson adopts global unified standards to ensure that each generator set is designed and manufactured in accordance with the highest British standards. .All factories implement world-class manufacturing processes.Each factory is ISO 9001 and ISO 14001 certified to ensure delivery quality. Wilson has a global logistics chain and a network of 370 dealers. Wilson can provide reliable product and service support no matter when and where users are. Product advantages and details Wilson Advantage: 1.Product advantages *Startup performance:It takes 5 seconds to start cranking to reach a stable state, and it takes about 15 seconds to reach full load. *Loading capacity:One-step loading capacity exceeds 50% *Power density:High power density, small unit size *Maintenance of the economy:Some parts of the 720-2000kw unit are interchangeable to reduce costs - the advantage of the high power section *Extended warranty service---60-month extended warranty service 2.service advantage *Customized services Wilson has a solution team of more than 200 people to design and produce customized products according to customers' special needs. *,Advanced control and parallel system *Remote cooling device *Emission silencer system *Rainproof and anti-speaker box *High insulation level *Customized testing 3.Complete solution-pre-sales support *Equipment load calculation and generator set selection: According to the project equipment load requirements, calculate the actual power supply demand, taking into account reliability and economy *Deepening of the engine room design: Based on project requirements and actual site conditions, deepen the diesel engine room design plan and provide professional suggestions; including diesel engine load-bearing foundation, engine room ventilation system, oil system, cable bridge, distribution cabinet layout, diesel engine room Hoisting etc. 4. Complete solution-after-sales support *Provide professional product training *FG Wilson Original Parts Consulting Help *Ensure timely supply and delivery of parts *Complete warranty, extended warranty and customer service agreements Product certification information P1101-1 model product specific information Engine Make Perkins Engine Model: 4008TAG2 Alternator Make Leroy Somer Alternator Model: LL7224P Control Panel: DSE7410 Base Frame: Heavy Duty Fabricated Steel Circuit Breaker Type: Options Available Frequency: 50 HZ 60 HZ Engine Speed: RPM rpm 1800 Fuel Tank Capacity: litres (USgal) () Fuel Consumption Prime litres (USgal)/hr 221.2 (58.4) Fuel Consumption Standby litres (USgal)/hr 244.4 (64.6) Engine Technical Data No. of Cylinders Alignment Cycle Bore Stroke Induction Cooling Method Governing Type Governing Class Compression Ratio Displacement Moment of Inertia: Voltage Ground Battery Charger Amps Engine Weight Dry Engine Weight Wet mm (in) mm (in) L (cu. in) kg m² (lb/in²) kg (lb) kg (lb) 8 IN LINE 4 STROKE 160 (6.3) 190 (7.5) TURBOCHARGED WATER ELECTRONIC ISO 8528 13.6:1 30.6 (1864.9) 15.62 (53376) 24 Negative 40 3250 (7165) 3428 (7557) Engine Performance Data 50 Hz 60 Hz Engine Speed rpm 1800 Gross Engine Power Prime Gross Engine Power Standby BMEP Prime kW (hp) kW (hp) kPa (psi) 898 (1204) 1004 (1346) 1959 (284.1) BMEP Standby kPa (psi) 2190 (317.7) Fuel Filter Type: Replaceable Element Recommended Fuel: Class A2 Diesel Fuel Consumption at 110 % Load 100 % Load 75 % Load 50 % Load 50 Hz Prime: l/hr (USgal/hr) 50 Hz Standby l/hr (USgal/hr) - 60 Hz Prime l/hr (USgal/hr) 244.4 (64.6) 221.2 (58.4) 165.8 (43.8) 114.1 (30.1) 60 Hz Standby l/hr (USgal/hr) - 244.4 (64.6) 182 (48.1) 124.2 (32.8) Air System 50 Hz 60 Hz Air Filter Type: Replaceable Element Combustion Air Flow Prime Combustion Air Flow Standby Max. Combustion Air Intake Restriction m³/min (cfm) m³/min (cfm) kPa 72 (2543) 77 (2719) 3.7 (14.9) Cooling System 50 Hz 60 Hz Cooling System Capacity l (USgal) 153 (40.4) Water Pump Type: Heat Rejected to Water & Lube Oil: Prime Heat Rejected to Water & Lube Oil: Standby Heat Radiation to Room*: Prime Heat Radiation to Room*: Standby Radiator Fan Load: Radiator Cooling Airflow: kW (Btu/min) kW (Btu/min) kW (Btu/min) kW (Btu/min) kW (hp) m³/min (cfm) Centrifugal 337 (19165) 375 (21326) 126 (7165) 154 (6300) 56 (75.1) 1461 (51595) External Restriction to Cooling Airflow: Pa (in H2O) 196 (0.8) *: Heat radiated from engine and alternator Designed to operate in ambient conditions up to 50°C (122°F). Contact your loc

Request a quote