Emergency Power Diesel Generator Set 400kw 500kVA Industrial Genset Generator

Starting from

SAR 131,250

About this product

Brief introduction: Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models. With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad. ShangHai Diesel Engine Generator Set GF/GFS-SC Series Generator with ShangHai Diesel Egnine 50Hz Generator Set Performance Engine Specification Open Genset Soundproof type Genset Model 50Hz Output Engine Model Cylinder Governor Displacement Dimension Weight Dimension Weight 50Hz Prime Standby Cons 100%(L/H) L L*W*H (mm) KG L*W*H(mm) KG KVA KW KVA KW GF/GFS-SC63 63 50 69 55 15.1 SC4H95D2 4L Elec 4.3 1980*880*1530 1006 2900*1080*2050 1800 GF/GFS-SC80 80 64 88 70 19 SC4H115D2 4L Elec 4.3 1980*880*1530 1066 2900*1080*2050 1800 GF/GFS-SC100 100 80 110 88 22.2 SC4H160D2 4L Elec 4.3 2000*930*1600 1141 2900*1080*2050 1850 GF/GFS-SC113 113 90 124 99 25 SC4H160D2 4L Elec 4.3 2000*930*1600 1141 2900*1080*2050 1850 GF/GFS-SC160 160 128 176 140 35.7 SC8D220D2 6L Elec 8.27 2440*1080*1800 1536 3500*1080*2150 2350 GF/GFS-SC170 170 136 187 150 36.5 SC7H230D2 6L Elec 6.5 2440*980*1700 1536 3500*1080*2150 2350 GF/GFS-SC180 180 144 198 158 40.7 SC8D250D2 6L Elec 8.27 2490*1080*1800 1604 3700*1100*2150 2400 GF/GFS-SC225 225 180 247 198 49.6 SC9D310D2 6L Elec 8.82 2490*1080*1800 1705 3700*1100*2150 2550 GF/GFS-SC250 250 200 275 220 54.1 SC9D340D2 6L Elec 8.82 2600*1080*1800 1776 3700*1100*2150 2550 GF/GFS-SC300 300 240 330 264 67.5 SC13G420D2 6L Elec 12.88 3030*1400*1900 2896 4350*1500*2220 3990 GF/GFS-SC313 313 250 344 275 70.4 SC13G420D2 6L Elec 12.88 3030*1400*1900 2896 4350*1500*2220 3990 GF/GFS-SC375 375 300 413 330 81.2 SC15G500D2 6L Elec 14.16 3030*1400*1900 3044 4350*1500*2220 4100 GF/GFS-SC450 450 360 495 396 100.4 SC25G610D2 12V Elec 25.8 3630*1720*2250 4078 4650*1800*2520 5300 GF/GFS-SC500 500 400 550 440 113.1 SC25G690D2 12V Elec 25.8 3630*1720*2250 4078 4650*1800*2520 5300 GF/GFS-SC625 625 500 687 550 141 SC27G830D2 12V Elec 26.6 3630*1720*2250 4328 4950*2000*2520 6000 GF/GFS-SC750 750 600 825 660 174.9 SC33W990D2 6L Elec 32.8 4360*1620*2160 6820 20 container 10000 -------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------ Helpful tips on Generator Set Fault When fault occurs during generator set running,could do primary judgement according to following tips. Icon Indicator Light Reason Fault Analysis and Solve Method High Water Temperature Alarm High Water Temperature Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. Low Oil Pressure Alarm Low Oil Pressure Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. Low Fuel Level Alarm Low Fuel Level Alarm When Fuel level has been detected by sensor fitted to the daily tank,the light is off. Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. Battery Charger Fault Alarm Battery Charger Fault Alarm The Charing System has fault while engine still running,the light is off. Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. Crank Failure Alarm Crank Failure Alarm When Generator set fail three times(or six times) in arow starting,the light is on It is caused by Oil Supply System or Re-Start System Failure. Overload or Breaker Tripping Alarm Overload or Breaker Tripping Alarm When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.

Request a quote