Diesel Power Generator 1000kVA 1250kVA 1350kVA 1500kVA 1875kVA 1850kVA 2000kVA 2250kVA 2500kVA Perkins Engine Electric Standby Generators Genset Manufacturer
Starting from
SAR 948,750
Specifications
| Listing type | Product |
|---|---|
| Minimum order | 1 |
About this product
Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators. With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. Generator Introduction Silent/Open/Containerized Type diesel generator with Perkins Engine for construction/factory/building/power plant -Power by Perkins engine -With Stamford / Leroy Somer / Marathon alternator -With ABB MCCB & Electronic Components -Electric start with battery -10 hours Lasting Base Integrated fuel Tank -Strictly comply with ISO9001/CE -24*365 hours global after-sale services -Option:ATS, Deepsea / ComAp controller VIEW MORE PRODUCTS CLIK HERE... Specification Powered by Perkins 50HZ 220-440 V 10-2500KVA Model LTP PRP Engine KVA / KW KVA/KW Model Origin MC10P 10 8 9 7 403A-11G1 CN/UK MC10P 10 8 9 7 403D-11G CN MC14P 14 11 13 10 403A-15G1 CN MC14P 14 11 13 10 403D-15G CN MC16P 16 13 15 12 403A-15G2 CN MC23P 23 18 20 16 404A-22G1 CN MC23P 23 18 20 16 404D-22G CN MC30P 30 24 28 22 404D-22TG CN MC33P 33 26 30 24 1103A-33G UK/IN MC50P 50 40 45 36 1103A-33TG1 UK/IN MC66P 66 53 60 48 1103A-33TG2 UK/IN MC72P 72 57 65 52 1104A-44TG1 CN MC88P 88 70 80 64 1104C-44TAG1 CN MC88P 88 70 80 64 1104A-44TG2 CN MC113P 113 90 100 80 1104C-44TAG2 CN MC150P 150 120 135 108 1106A-70TG1 CN MC165P 165 132 150 120 1106A-70TAG2 CN MC200P 200 160 180 144 1106A-70TAG3 CN MC220P 220 176 200 160 1106A-70TAG4 CN MC220P 220 176 200 160 1206A-E70TTAG1 UK MC250P 250 200 225 180 1506A-E88TAG2 USA MC250P 250 200 225 180 1206A-E70TTAG2 UK MC275P 275 220 250 200 1206A-E70TTAG3 UK MC339P 339 271 306 245 1706A-E93TAG1 USA MC383P 383 306 348 278 1706A-E93TAG2 USA MC275P 275 220 250 200 1506A-E88TAG3 USA MC330P 330 264 300 240 1506A-E88TAG5 USA MC400P 400 320 350 280 2206C-E13TAG2 USA MC450P 450 360 400 320 2206C-E13TAG3 USA MC500P 500 400 450 360 2506C-E15TAG1 USA MC550P 550 440 500 400 2506C-E15TAG2 USA MC660P 660 528 600 480 2806C-E18TAG1A USA MC715P 715 572 650 520 2806A-E18TAG2 USA MC825P 825 660 750 600 4006-23TAG2A UK/IN MC880P 880 704 800 640 4006-23TAG3A UK/IN MC1000P 1000 800 900 720 4008TAG1A UK/IN MC1100P 1100 880 1000 800 4008TAG2A UK/IN MC1100P 1100 880 1000 800 4008TAG2 UK/IN MC1250P 1250 1000 1125 900 4008-30TAG3 UK/IN MC1375P 1375 1100 1250 1000 4012-46TWG2A UK/IN MC1500P 1500 1200 1350 1080 4012-46TWG3A UK/IN MC1650P 1650 1320 1500 1200 4012-46TAG2A UK/IN MC1875P 1875 1500 1688 1350 4012-46TAG3A UK/IN MC2000P 2000 1600 1850 1480 4016TAG1A UK/IN MC2250P 2250 1800 2000 1600 4016TAG2A UK/IN MC2500P 2500 2000 2250 1800 4016-61TRG3 UK/IN MORE SEPC. CONTACT US... Genset Workshop 1.Q: What is your MOQ of this item? A:1 Set 2.Q: What are your payment terms? A:30% TT as deposit,70% TT before Shipment or 100% LC at sight 3.Q:What's the warranty time of diesel generators? A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first. 4.Q:Can you accept the customized products? A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples 5.Q:What's the delivery time ? A:20 to 35 days after receiving your payment in advance. 6.Q:Do you offer OEM service? A: Yes 7.Q:What is the power range do you have? A:Mecca Power assemble genset from 2 to 4000kva 8.Q:What's your special compare to other manufacturer? A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price. Item Service Option Delivery Time 1 Engine Doosan, Mtu, Mitsubishi, SME, Volvo, Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect. Marine and industry use Diesel, gas 2-45days 2 Alternator Stam ford, Leroysomer, Meccalte, Marathon and customer requested alternators Medium and high voltage, Marine and industry use High IP Grade CT Drop kits, PMG, AVR 2-15 days 3 Radiator Fast, Beworld brand Original Radiator come with engine Local made radiator with authorization by engine supplier 2-7days 4 Canopies Powder coated and form mounted canopy,completely break down with hings, locks, raincap,bolts,screws, etc. Exhaust pipe and flanges Standard silent type canopy package Denyo type canopy package Rental type canopy package Telecom type canopy package Super silent type canopy package Containerized type canopy package Customerized type canopy package 10days 5 Base frame Standard base or simple iron base Anti-Vibration mountings With/without tank, base tank volume no limited Fuel gauges and high pressure fuel pipes 3days 6 Control system Controller: ComAp, DeepSea, Datacom, SmartGen etc. Breaker:Delixi,ABB, Chint, etc. Battery switch, battery charger, emergency stop botton, indicator, meters, CT and all wiring and harness. Batteries and cables Speed & lub oil & water temp sensors, A package of standard parts for assembly 3days 7 Exhaust System Industrial and residential silencer Flexible connects and elbow 3days 8 Others Special demands -----------------------------------------------------------------------------------------------MAITAINENCE------------------------------------------------------------------------------------------- General Troubleshooting This section lists the generating set for some common fault, the reasons for the failure and determines the method of fault. General operators can determine their own fault and note, maintenance it according to the brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation. Please remember the following suggestions before repairing: - Make sure that study the failure carefully before any operation. - Repair with the easiest way and most commonly used method. - Find the exact causes of failure and completely solve the fault. 1. Generator Sets Description of this section is for reference only. If the following failure occurs please contact the repairing agents. (Some models of control panel installed only parts of the following warning indicator light) Icon Indicator Light Reason Fault Analysis Low oil pressure alarm Low oil pressure alarm When oil pressure does not reduce normally, the light is on. -General because of a lack of oil or lubrication system failure caused by (refueling or replacing the oil filter) -When occurs this fault should automatically shutdown generator sets immediately. High water temperature alarm High water temperature alarm When the water temperature has risen to a level higher than or equal to the sensor setting, the light is on. -General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. Low fuel level alarm Low fuel level alarm When a fuel level has been detected by the sensor fitted to the daily tank, the light is on. -General because of a lack of water or oil shortage, or overload. -When occurs this fault should automatically shutdown generator sets immediately. Battery charger fault alarm Battery charger fault alarm If the charging system has fault, when engine running, the light is off. -Battery charging system fault caused. -The light is on at the initial start, when the charger reaches a certain speed, the light is off. -This failure will not lead to automatic shutdown generating units. Crank failure alarm Crank failure alarm When the generator set failed three times (or six times) in a row starting, the light is on. -Oil supply system or re-start the system failure caused. Overload or breaker tripping alarm Overload or breaker tripping alarm When overloading or Short circuit, the light is on. Tripping circuit breakers cause generator set load out. -In this fault, it need to load or unload some parts to eliminate short-circuit, and then re-close the circuit breaker. Introduction of Maintenance grade(Interval) for the generator set A Level Maintenance Interval (Daily Maintenance) 1. Check Daily Report of Genset . 2. Check fuel level and coolant level. 3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or other damage. 4. Check the Air filter. The air filter should be replaced when necessary . 5. Release fuel tank and fuel filter's water and sediment. 6. Check the water cooling filter. 7. Check starting battery and electrolyte, add electrolyte when necessary. 8. Check the starter, check noisy defect. 9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net. B Level Maintenance Interval (Less than 400 hours) 1. Repeatedly check A Level Daily Maintenance steps. 2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice and real fact. 3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF Grade of American Petroleum Institute. 4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or it can be replaced. The replacement must be according to the environment and real fact. 5. Replace the cooling system and add coolant concentration. 6. Clean the crankshaft and inlet, outlet air- filter net. C Level Maintenance Interval (2000-3000 hours), Please do as follows: 1. Repeatedly check A and B Level Daily Maintenance steps. 2. Remove the tap of valve, clean and wash oil dirt and sludge. 3. Fasten snails from each part (including running parts and fixed parts) 4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine. 5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary. 6. Check and adjust valve clearance. 7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary. 8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; clean and wash water tank radiator fins, then check the using capability of thermostat. Current Repair (D Level Maintenance)(3000-4000 hours) 1. Check valve, valve seat and other wearing, repair or change it when necessary. 2. Check P pump, quality of injection, repair and adjust it when necessary. 3. Check and adjust connecting rod and fastening twisting torque. 4. Check and adjust valve clearance. 5. Check the trip of injector. 6. Check and adjust tension of fan and generating belt. 7. Clean and wash accumulation of carbon in inlet pipes. 8. Clean and wash the core of air cooler. 9. Clean and wash the whole oil lubrication system. 10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron. Medium Repair (6000-8000 hours) 1. Including the items of minor repair. 2. Disassemble generator(except crankshaft) 3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary. 4. Check fuel supplying system, adjust oil pump and injector. 5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator. Overhaul (9000-15000hours) 1. Including the items of intermediate repair. 2. Disassemble all the parts in the generator. 3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake and exhaust valve, a whole set of tools for generator repair 4. Adjust oil pump, injector and replace pump core, injector 5. Replace a whole set of repair tools for turbo charger and a repair set for water pump. 6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary