10kw 20kw30kw50kw Hom Use Factory Use Standby Power Diesel Generator

Starting from

SAR 257,126.25

About this product

Basic Info: Genset model: King Power/KPG875C Installation Method: Fixed Fuel type: Diesel Cooling Method: Water Cooling Conditions of use: Land use Usage: Common/standby units Excitation Mode: AC Rotating Exciter Excitation Mode: AC Rotating Exciter Output Type: AC Three Phase Stroke: Four Stroke Trademark: King Power Out-put Power(KW/KVA): 700/875 Origin: Shenzhen, China Dimension(MM): 4160*1810*2400 Sound Level(DB): 60-105 Gross weight(KGS): 6442 Speed(RPM): 1500/1800 Engine brand&Model: Joint venture KTA38-G2 HS code: 8502131000 Advantage: Anti-Vibration, Fuel-saving, high Efficiency Alternator brand: Robot/Marathon/Leroy-somer Optional Parts: Parallel System, Fuel Tank, wheels, ATS Standard Accessory: Exhaust Silencer, Flexible Pipe, Battery Cables, battery, air breaker Environment: Work in Any Kinds of Harsh Climate Warranty Period: 1 Year or 1000 Hours from the genset's delivery from the seller, subject to whichever comes first. Package & Payment & Delivery Date Package: PEE/ Ply-wood packing. Payment term: 30% T/T as deposit, 70% balance shall be paid before delivery. Or 100% irrevocable L/C at sight. Price term: FOB, CFR, CIF, EXW Delivery time: 20-35 working days after getting the deposit. Genset features 1. Engine and alternator shall be mounted on a same frame steel skid. 2. Built-in damper for anti-vibration. 3. World-famous diesel engine brand. 4. World-famous AC alternators brand. 5. Intelligent and reliable control module. 6. Full range protection function and alarm shutdown feature. 7. Supply of all the necessary spare parts. 8. High price performance ratio. 9. After-sale service centers located all over the world. Alternator Feature 1. Brush-less, 4 poles, rotation magnet. 2. IP21-23) enclosure is standard for all industrial alternators. 3. The insulation system is Class H 4. Simple installation and maintenance, with easy access to terminals, rotating diodes and coupling bolts. 5. Wide range of flange adapters and single bearing disc coupling. 6. Standard 2/3 pitch windings avoid excessive neutral currents 7. AVR auto voltage regulator, auto exciter, auto adjustment Standard Accessory Steel base frame, 3 meters smoke pipe, Exhaust silencer, Flanges, bellows, Battery and connecting wires, Operation manual and documents, load test report, water temperature sensor, oil-pressure sensor, air breakers, control panel, maintaining tools, etc. Optional Accessory Water-proof canopy, engine coolant and oil heater, Alternator space heater, heat exchanger, remote control system with RS232/485 communication interface, floating battery charger, fuel-water separator, daily or base fuel tank, ATS, VTS, paralleling system, synchronizer, moving trailer or wheels, sound-proof canopy, extra spare parts. Silent Canopy performance 1. Steel Weatherproof Canopy 2. Built In Fuel Tank 3. Built In Control Panel 4. Built In Start Battery 5. Power Output Rapid Insert 6. Doors for Looking or maintaining 7. Air Louver for Intake & Exhaust 8. Exhaust Gas Silencer 9. Assembled smoke pipes 10. Filled with high quality silencer cotton 11. Strong sense of design 12. Easy for operating ATS System If the generator set will be used as a standby power, the auto transfer switch (ATS) is necessary and essential. Because ATS can automatically transfer load from Mains power to generator set. In normal, when the Main power fails or voltage drops below 80% of the normal voltage, ATS will auto start standby generator set after a preset time of 0-10 sec (adjustable according to the users). Once generator reaches at rated speed, the ATS will transfer the load to standby generator sets automatically. Quality Warranty Period One year or 1000hours from the genset's delivery from the seller, subject to whichever comes first. Customers can have get the warranty from both the engine or alternator suppliers and also from King Power during the warranty period. We promise to test every generator set before delivery. After-sale service King power provides free technical support and spare parts during the warranty period. We can also provide support to the customers, if the customers need us to help fix the installation or commission, only charging the necessary fees. All life-span technical support on line can be offered freely. 700KW Diesel Gen-sets Technical Data Genset brand and model King Power/KPG875C Out-put power (KW/KVA) 700/875 Engine brand & model Joint venture KTA38-G2 Alternator brand Robot/Marathon/Leroy-somer Fuel System PT fuel pump Fuel consumption at 75% load (L/h) 134.9 Engine Cylinder arrangement V-line Bore*stroke(MM) 159*159 Cubic capacity(L) 37.8 Compression ratio 14.5:1 Rated speed(RPM) 1500 /1800 Number of cylinders 12 Back pressure(KPa) <10KPA Sound level(DB) Open type ≤105 Silent type Custom made (60-90) Cooling system Fan,water coolant Electrical system Electron speed regulating Start system By electricity Engine filter system Paper filter Fuel tank capacity(L) Custom made Packing Custom made Rated current(A) 1263 Rated vo

Request a quote